{"id":2983,"date":"2026-10-01T22:28:25","date_gmt":"2026-10-01T14:28:25","guid":{"rendered":"https:\/\/kvagenset.com\/kva-calculator\/"},"modified":"2026-10-01T22:34:17","modified_gmt":"2026-10-01T14:34:17","slug":"kva-calculator","status":"publish","type":"page","link":"https:\/\/kvagenset.com\/id\/kva-calculator\/","title":{"rendered":"Kalkulator kVA Genset"},"content":{"rendered":"<p><!-- KVAGENSET \u9009\u578b\u5de5\u5177\u9875 T11 \/ kVA \u8ba1\u7b97\u5668 \u2014 \u7ed3\u6784\u4f9d\u636e docs\/\u7ad9\u70b9\u7ed3\u6784\u4e0e\u9875\u9762\u6a21\u677f\u89c4\u8303.md \u7b2c 4 \u8282 T9\uff1b\u8868\u5355\u7ed3\u6784\u4e0e\u811a\u672c\u7531 mu-plugin \u8f93\u51fa\uff08\u6b63\u6587\u5185\u8054 input\/select\/script \u4f1a\u88ab KSES \u5220\u9664\uff09 --><\/p>\n<section class=\"kv-section\">\n<div class=\"kv-container\">\n<p class=\"kv-eyebrow\">Alat ukur daya<\/p>\n<h1 class=\"kv-display\">Kalkulator kVA Genset<\/h1>\n<p class=\"kv-lede\">Masukkan beban yang Anda perkirakan akan berjalan dan kalkulator mengembalikan rating yang direkomendasikan dalam kVA. Perhitungannya memakai aritmetika yang benar-benar dipakai dalam penawaran: beban tersambung, faktor permintaan karena tidak semuanya berjalan bersamaan, kelonggaran untuk motor terbesar yang start, faktor daya 0,8 dan margin. Tidak ada yang dikirim ke mana pun sampai Anda menekan tombol.<\/p>\n<p>Hasilnya adalah titik awal untuk penawaran, bukan pengganti penawaran. Ketinggian, suhu ambien, kelembapan dan enclosure semuanya mengurangi kemampuan unit, dan daftar beban dengan beberapa motor besar yang start bersamaan dapat menggeser jawabannya satu kelas penuh.<\/p>\n<\/p><\/div>\n<\/section>\n<section class=\"kv-section kv-section--surface\">\n<div class=\"kv-container kv-form\">\n<p class=\"kv-eyebrow\">Langkah 1<\/p>\n<h2>Masukkan bebannya<\/h2>\n<p>Isi jumlah pada setiap beban yang Anda perkirakan berjalan bersamaan. Sisanya biarkan nol. Kolom rating tipikal adalah yang dipakai kalkulator untuk baris itu &#8211; ubah jumlahnya, bukan ratingnya, kecuali Anda tahu angka sebenarnya, dalam hal ini gunakan baris terakhir untuk menambahkan beban itu dengan kW-nya sendiri.<\/p>\n<div class=\"kv-table-wrap\">\n\t<table class=\"kv-table\">\n\t\t<thead>\n\t\t\t<tr><th scope=\"col\">Beban<\/th><th scope=\"col\">Rating umum<\/th><th scope=\"col\">Jumlah<\/th><th scope=\"col\">kW tersambung<\/th><\/tr>\n\t\t<\/thead>\n\t\t<tbody>\n\t\t\t<tr><td>Penerangan dan stopkontak umum, per 100 m2<\/td><td>2.0 kW<\/td><td><input type=\"number\" min=\"0\" step=\"1\" value=\"0\" id=\"kv-qty-0\" data-kw=\"2\" class=\"kv-calc-qty\" aria-label=\"Jumlah: Penerangan dan stopkontak umum, per 100 m2\"><\/td><td data-out=\"r0\">0.0<\/td><\/tr>\n\t\t\t<tr><td>AC split atau unit jendela<\/td><td>2.5 kW<\/td><td><input type=\"number\" min=\"0\" step=\"1\" value=\"0\" id=\"kv-qty-1\" data-kw=\"2.5\" class=\"kv-calc-qty\" aria-label=\"Jumlah: AC split atau unit jendela\"><\/td><td data-out=\"r1\">0.0<\/td><\/tr>\n\t\t\t<tr><td>AC packaged atau sentral, per 10 kW pendinginan<\/td><td>3.5 kW<\/td><td><input type=\"number\" min=\"0\" step=\"1\" value=\"0\" id=\"kv-qty-2\" data-kw=\"3.5\" class=\"kv-calc-qty\" aria-label=\"Jumlah: AC packaged atau sentral, per 10 kW pendinginan\"><\/td><td data-out=\"r2\">0.0<\/td><\/tr>\n\t\t\t<tr><td>Pompa air, sampai 3 kW<\/td><td>2.2 kW<\/td><td><input type=\"number\" min=\"0\" step=\"1\" value=\"0\" id=\"kv-qty-3\" data-kw=\"2.2\" class=\"kv-calc-qty\" aria-label=\"Jumlah: Pompa air, sampai 3 kW\"><\/td><td data-out=\"r3\">0.0<\/td><\/tr>\n\t\t\t<tr><td>Pompa air atau pompa proses, 5 sampai 15 kW<\/td><td>11.0 kW<\/td><td><input type=\"number\" min=\"0\" step=\"1\" value=\"0\" id=\"kv-qty-4\" data-kw=\"11\" class=\"kv-calc-qty\" aria-label=\"Jumlah: Pompa air atau pompa proses, 5 sampai 15 kW\"><\/td><td data-out=\"r4\">0.0<\/td><\/tr>\n\t\t\t<tr><td>Refrigerasi, walk-in atau cold room<\/td><td>3.0 kW<\/td><td><input type=\"number\" min=\"0\" step=\"1\" value=\"0\" id=\"kv-qty-5\" data-kw=\"3\" class=\"kv-calc-qty\" aria-label=\"Jumlah: Refrigerasi, walk-in atau cold room\"><\/td><td data-out=\"r5\">0.0<\/td><\/tr>\n\t\t\t<tr><td>Dapur, per dapur komersial<\/td><td>15.0 kW<\/td><td><input type=\"number\" min=\"0\" step=\"1\" value=\"0\" id=\"kv-qty-6\" data-kw=\"15\" class=\"kv-calc-qty\" aria-label=\"Jumlah: Dapur, per dapur komersial\"><\/td><td data-out=\"r6\">0.0<\/td><\/tr>\n\t\t\t<tr><td>Binatu, per lini<\/td><td>25.0 kW<\/td><td><input type=\"number\" min=\"0\" step=\"1\" value=\"0\" id=\"kv-qty-7\" data-kw=\"25\" class=\"kv-calc-qty\" aria-label=\"Jumlah: Binatu, per lini\"><\/td><td data-out=\"r7\">0.0<\/td><\/tr>\n\t\t\t<tr><td>Lift, per lift<\/td><td>15.0 kW<\/td><td><input type=\"number\" min=\"0\" step=\"1\" value=\"0\" id=\"kv-qty-8\" data-kw=\"15\" class=\"kv-calc-qty\" aria-label=\"Jumlah: Lift, per lift\"><\/td><td data-out=\"r8\">0.0<\/td><\/tr>\n\t\t\t<tr><td>Kompresor udara<\/td><td>15.0 kW<\/td><td><input type=\"number\" min=\"0\" step=\"1\" value=\"0\" id=\"kv-qty-9\" data-kw=\"15\" class=\"kv-calc-qty\" aria-label=\"Jumlah: Kompresor udara\"><\/td><td data-out=\"r9\">0.0<\/td><\/tr>\n\t\t\t<tr><td>Mesin las<\/td><td>20.0 kW<\/td><td><input type=\"number\" min=\"0\" step=\"1\" value=\"0\" id=\"kv-qty-10\" data-kw=\"20\" class=\"kv-calc-qty\" aria-label=\"Jumlah: Mesin las\"><\/td><td data-out=\"r10\">0.0<\/td><\/tr>\n\t\t\t<tr><td>Rak telekomunikasi atau server, per rak<\/td><td>5.0 kW<\/td><td><input type=\"number\" min=\"0\" step=\"1\" value=\"0\" id=\"kv-qty-11\" data-kw=\"5\" class=\"kv-calc-qty\" aria-label=\"Jumlah: Rak telekomunikasi atau server, per rak\"><\/td><td data-out=\"r11\">0.0<\/td><\/tr>\n\t\t\t<tr><td>Rectifier DC atau power plant, per 100 A pada 48 V<\/td><td>5.0 kW<\/td><td><input type=\"number\" min=\"0\" step=\"1\" value=\"0\" id=\"kv-qty-12\" data-kw=\"5\" class=\"kv-calc-qty\" aria-label=\"Jumlah: Rectifier DC atau power plant, per 100 A pada 48 V\"><\/td><td data-out=\"r12\">0.0<\/td><\/tr>\n\t\t\t<tr><td>Mesin perkakas atau motor kecil, sampai 7,5 kW<\/td><td>5.5 kW<\/td><td><input type=\"number\" min=\"0\" step=\"1\" value=\"0\" id=\"kv-qty-13\" data-kw=\"5.5\" class=\"kv-calc-qty\" aria-label=\"Jumlah: Mesin perkakas atau motor kecil, sampai 7,5 kW\"><\/td><td data-out=\"r13\">0.0<\/td><\/tr>\n\t\t\t<tr><td>Crusher, mill atau motor proses besar<\/td><td>75.0 kW<\/td><td><input type=\"number\" min=\"0\" step=\"1\" value=\"0\" id=\"kv-qty-14\" data-kw=\"75\" class=\"kv-calc-qty\" aria-label=\"Jumlah: Crusher, mill atau motor proses besar\"><\/td><td data-out=\"r14\">0.0<\/td><\/tr>\n\t\t\t<tr><td>Beban lain, masukkan kW kerja per unit<\/td><td><input type=\"number\" min=\"0\" step=\"0.1\" value=\"0\" id=\"kv-kw-other\" data-kw-for=\"r15\" class=\"kv-calc-other\" aria-label=\"kW kerja per unit beban lain\"><\/td><td><input type=\"number\" min=\"0\" step=\"1\" value=\"0\" id=\"kv-qty-15\" data-kw=\"0\" data-kw-src=\"r15\" class=\"kv-calc-qty\" aria-label=\"Jumlah beban lain\"><\/td><td data-out=\"r15\">0.0<\/td><\/tr>\n\t\t<\/tbody>\n\t<\/table>\n<\/div>\n<\/div>\n<\/section>\n<section class=\"kv-section\">\n<div class=\"kv-container kv-form\">\n<p class=\"kv-eyebrow\">Langkah 2<\/p>\n<h2>Empat angka yang menggeser hasil<\/h2>\n<p>Dua di antaranya adalah pertimbangan teknis, bukan hasil pengukuran, dan itulah sebabnya dua penawaran untuk gedung yang sama bisa berbeda satu kelas penuh. Nilai bawaan adalah yang kami pakai bila tidak ada informasi lain.<\/p>\n<div class=\"kv-table-wrap\">\n\t<table class=\"kv-table\">\n\t\t<thead>\n\t\t\t<tr><th scope=\"col\">Item<\/th><th scope=\"col\">Nilai<\/th><th scope=\"col\">Mengapa penting<\/th><\/tr>\n\t\t<\/thead>\n\t\t<tbody>\n\t\t\t<tr><td><label for=\"kv-calc-largest\">Motor terbesar, kW kerja<\/label><\/td><td><input type=\"number\" min=\"0\" step=\"0.1\" value=\"0\" id=\"kv-calc-largest\"><\/td><td>Arus start motor terbesar, bukan beban kerjanya, yang biasanya menentukan rating.<\/td><\/tr>\n\t\t\t<tr><td><label for=\"kv-calc-start\">Bagaimana motor itu start<\/label><\/td><td><select id=\"kv-calc-start\"><option value=\"6\">Direct on line<\/option><option value=\"3\">Starter star-delta<\/option><option value=\"1.5\" selected>Soft starter atau variable speed drive<\/option><option value=\"1\">Tidak ada motor besar, atau start tanpa beban<\/option><\/select><\/td><td>Motor direct-on-line menarik enam kali arus kerjanya pada detik-detik pertama.<\/td><\/tr>\n\t\t\t<tr><td><label for=\"kv-calc-demand\">Faktor permintaan<\/label><\/td><td><select id=\"kv-calc-demand\"><option value=\"1\">1,0 - semuanya berjalan bersamaan<\/option><option value=\"0.9\">0,9 - sebagian besar berjalan bersamaan<\/option><option value=\"0.8\" selected>0,8 - kasus komersial yang umum<\/option><option value=\"0.7\">0,7 - campuran beragam beban intermiten<\/option><\/select><\/td><td>Tidak setiap beban tersambung menyala pada saat yang sama, dan unit yang diukur untuk total tersambung akan kelebihan kapasitas.<\/td><\/tr>\n\t\t\t<tr><td><label for=\"kv-calc-margin\">Margin<\/label><\/td><td><select id=\"kv-calc-margin\"><option value=\"1.1\">10% - beban sudah diketahui dengan baik<\/option><option value=\"1.2\" selected>20% - kelonggaran yang umum<\/option><option value=\"1.25\">25% - beban masih mungkin bertambah<\/option><option value=\"1.3\">30% - pabrik akan diperluas<\/option><\/select><\/td><td>Ruang untuk beban yang belum Anda sebutkan, dan untuk unit yang tidak selamanya baru.<\/td><\/tr>\n\t\t<\/tbody>\n\t<\/table>\n<\/div>\n<\/div>\n<\/section>\n<section class=\"kv-section kv-section--surface\">\n<div class=\"kv-container\">\n<p class=\"kv-eyebrow\">Hasil<\/p>\n<h2>Rating yang direkomendasikan<\/h2>\n<div class=\"kv-table-wrap\">\n\t<table class=\"kv-table\">\n\t\t<caption>Perhitungannya, langkah demi langkah. Ubah input mana pun di atas dan angka-angka ini mengikuti.<\/caption>\n\t\t<thead>\n\t\t\t<tr><th scope=\"col\">Langkah<\/th><th scope=\"col\">Nilai<\/th><\/tr>\n\t\t<\/thead>\n\t\t<tbody>\n\t\t\t<tr><td>Beban tersambung<\/td><td><span data-out=\"running\">0.0<\/span> kW<\/td><\/tr>\n\t\t\t<tr><td>Setelah faktor permintaan<\/td><td><span data-out=\"design\">0.0<\/span> kW<\/td><\/tr>\n\t\t\t<tr><td>Kelonggaran start untuk motor terbesar<\/td><td><span data-out=\"start\">0.0<\/span> kW<\/td><\/tr>\n\t\t\t<tr><td>Beban puncak yang harus dibawa<\/td><td><span data-out=\"peak\">0.0<\/span> kW<\/td><\/tr>\n\t\t\t<tr><td>Dengan margin, pada faktor daya 0,8<\/td><td><span data-out=\"kva\">0.0<\/span> kVA<\/td><\/tr>\n\t\t\t<tr><td>Rating standar yang direkomendasikan<\/td><td><strong data-out=\"class\">0 kVA<\/strong><\/td><\/tr>\n\t\t<\/tbody>\n\t<\/table>\n<\/div>\n\n<p class=\"kv-note\">Rekomendasi dibulatkan ke atas ke rating standar, karena genset dibuat dalam tingkatan, bukan sesuai pesanan. Bila angkanya sedikit di bawah 200 kVA, jawaban yang dikutip biasanya 200 kVA, bukan 190, dan itu disengaja: kenaikan kecil itu mengembalikan penurunan kemampuan yang diambil oleh hari bersuhu 38 &deg;C.<\/p>\n<p><a class=\"kv-btn kv-btn--primary\" id=\"kv-calc-quote\" href=\"\/id\/request-a-quote\/\">Minta penawaran untuk rating ini<\/a><br \/>\n      <a class=\"kv-btn kv-btn--tertiary\" href=\"https:\/\/wa.me\/8615886706939\" target=\"_blank\" rel=\"noopener\">Chat via WhatsApp<\/a><\/p>\n<\/p><\/div>\n<\/section>\n<section class=\"kv-section\">\n<div class=\"kv-container\">\n<p class=\"kv-eyebrow\">Pertanyaan<\/p>\n<h2>Pertanyaan tentang kalkulator<\/h2>\n<div class=\"kv-faq\">\n<details>\n<summary>Mengapa kalkulator meminta faktor permintaan?<\/summary>\n<p>Karena unit yang diukur untuk jumlah seluruh beban tersambung akan berjalan pada sebagian kecil ratingnya hampir sepanjang umurnya. Binatu, dapur dan instalasi kolam hotel jarang berjalan pada beban penuh bersamaan; mesin perkakas pabrik bersifat intermiten. Faktor permintaan adalah pertimbangan teknis yang mengubah daftar tersambung menjadi beban berjalan, dan itulah sebabnya dua insinyur dapat menghargai lokasi yang sama secara berbeda.<\/p>\n<\/details>\n<details>\n<summary>Mengapa motor terbesar ditangani terpisah?<\/summary>\n<p>Karena motor yang start langsung (direct on line) menarik arus sekitar enam kali arus kerjanya selama beberapa detik pertama, dan transien itu &#8211; bukan beban tetapnya &#8211; yang biasanya menentukan rating. Unit yang mampu membawa beban kerja dengan nyaman masih bisa macet atau turun tegangannya ketika motor besar start, sehingga kelonggaran start ditambahkan di atas beban desain, bukan dirata-ratakan ke dalamnya.<\/p>\n<\/details>\n<details>\n<summary>Apakah ketinggian atau suhu mengubah hasilnya?<\/summary>\n<p>Ya, dan kalkulator tidak menerapkan keduanya. Mesin diesel kehilangan daya saat suhu ambien naik di atas sekitar 40 &deg;C dan saat ketinggian naik di atas sekitar 1000 m, dan penurunan itu diterapkan pada unit yang Anda beli, bukan pada beban Anda. Lokasi di ketinggian dalam ruang mesin yang panas bisa memerlukan kelas di atasnya untuk beban yang sama: beri tahu kami kondisi lokasi dan penawaran akan menerapkannya.<\/p>\n<\/details>\n<details>\n<summary>Apa perbedaan kVA dan kW di sini?<\/summary>\n<p>kW adalah daya nyata dan kVA adalah daya semu; keduanya dihubungkan oleh faktor daya, yang untuk genset biasanya 0,8. Unit 500 kVA menghasilkan 400 kW pada faktor daya 0,8. Kalkulator bekerja dalam kW karena beban dinilai dalam kW, lalu mengonversi ke kVA pada 0,8 di akhir, itulah sebabnya rating yang direkomendasikan selalu lebih besar daripada beban puncak dalam kW.<\/p>\n<\/details><\/div>\n<\/p><\/div>\n<\/section>\n<section class=\"kv-section kv-section--surface\">\n<div class=\"kv-container\">\n<p class=\"kv-eyebrow\">Terkait<\/p>\n<h2>Related pages<\/h2>\n<ul class=\"kv-cards\">\n<li class=\"kv-card\">\n        <a href=\"\/id\/diesel-generator\/\"><\/p>\n<h3>Genset diesel 20 kVA hingga 2000 kVA<\/h3>\n<p>Bagaimana setiap rentang dipakai dan apa yang menentukan rating.<\/p>\n<p>        <\/a>\n      <\/li>\n<li class=\"kv-card\">\n        <a href=\"\/id\/blog\/how-to-size-a-diesel-generator\/\"><\/p>\n<h3>Cara menentukan ukuran genset diesel<\/h3>\n<p>Versi lebih panjang dari perhitungan di halaman ini, dengan contoh perhitungan.<\/p>\n<p>        <\/a>\n      <\/li>\n<li class=\"kv-card\">\n        <a href=\"\/id\/blog\/prime-vs-standby-power\/\"><\/p>\n<h3>Rating prime dan standby<\/h3>\n<p>Mengapa mesin yang sama mencantumkan dua angka berbeda.<\/p>\n<p>        <\/a>\n      <\/li>\n<li class=\"kv-card\">\n        <a href=\"\/id\/silent-diesel-generator\/\"><\/p>\n<h3>Genset silent<\/h3>\n<p>Apa yang ditambahkan kanopi akustik pada luas dan biaya.<\/p>\n<p>        <\/a>\n      <\/li>\n<li class=\"kv-card\">\n        <a href=\"\/id\/philippines\/\"><\/p>\n<h3>Philippines<\/h3>\n<p>60 Hz, 220\/440 V dan kondisi yang mengubah konstruksinya.<\/p>\n<p>        <\/a>\n      <\/li>\n<li class=\"kv-card\">\n        <a href=\"\/id\/request-a-quote\/\"><\/p>\n<h3>Minta penawaran<\/h3>\n<p>Kirim daftar beban dan kondisi lokasi, dan kami menentukan ukuran unitnya.<\/p>\n<p>        <\/a>\n      <\/li>\n<\/ul><\/div>\n<\/section>\n<section class=\"kv-section\">\n<div class=\"kv-container\">\n<div class=\"kv-cta\">\n<h2>Punya daftar beban tetapi belum tahu ratingnya?<\/h2>\n<p>Kirim daftarnya lewat WhatsApp atau formulir dan kami akan mengembalikan rating, konfigurasi dan harganya.<\/p>\n<p><a class=\"kv-btn kv-btn--inverse\" href=\"\/id\/request-a-quote\/\">Minta penawaran<\/a><\/p>\n<\/p><\/div>\n<\/p><\/div>\n<\/section>","protected":false},"excerpt":{"rendered":"<p>Sizing tool Generator kVA Calculator Enter the loads you expect to run and the calculator returns a recommended rating in [&hellip;]<\/p>\n","protected":false},"author":0,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"disabled","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"default","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"footnotes":""},"class_list":["post-2983","page","type-page","status-publish","hentry"],"_links":{"self":[{"href":"https:\/\/kvagenset.com\/id\/wp-json\/wp\/v2\/pages\/2983","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/kvagenset.com\/id\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/kvagenset.com\/id\/wp-json\/wp\/v2\/types\/page"}],"replies":[{"embeddable":true,"href":"https:\/\/kvagenset.com\/id\/wp-json\/wp\/v2\/comments?post=2983"}],"version-history":[{"count":2,"href":"https:\/\/kvagenset.com\/id\/wp-json\/wp\/v2\/pages\/2983\/revisions"}],"predecessor-version":[{"id":3005,"href":"https:\/\/kvagenset.com\/id\/wp-json\/wp\/v2\/pages\/2983\/revisions\/3005"}],"wp:attachment":[{"href":"https:\/\/kvagenset.com\/id\/wp-json\/wp\/v2\/media?parent=2983"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}