This is a used 1250 kVA diesel generating set, offered as an individual unit and photographed where it stands. The set is built on a KTA50-G3 engine. The alternator is a LVI634.

SKU: kvg-cummins-1250kva-273 Category:

1250 kVA power class

Used Cummins 1250 kVA Diesel Generator

This is a used 1250 kVA diesel generating set, offered as an individual unit and photographed where it stands. The set is built on a KTA50-G3 engine. The alternator is a LVI634.

Every figure on this page is taken from the unit itself, and anything we could not confirm is left blank rather than estimated. Photographs on this page are actual unit photos of this set, and the set can be inspected before it ships.

Request a quote for this set Ask on WhatsApp

Spesifikasi

Key parameters

Parameters as recorded on this unit. Rows we could not confirm are left out rather than estimated.
Parameter Nilai
Model kvg-cummins-1250kva-273
Condition Used
Daya utama 1250 kVA
Standby power 1400 kVA
Mesin KTA50-G3
Alternator LVI634

Fuel consumption, dimensions and weight are confirmed against the engine datasheet when we quote, and are not estimated here.

Engine and fuel

Cummins datasheet for this rating

Figures Cummins publishes for the 1250 kVA build. Where the engine on this unit differs from the datasheet, it is listed separately.
Parameter Nilai
Cummins datasheet engine KTA50-G3
Cummins datasheet alternator LVI634
Engine configuration CCEC (Chongqing Cummins), V16, 50 L
Fuel consumption at 100% load 202 L/h
Speed / frequency 1500 rpm / 50 Hz
Rated voltage 400/230 V, three-phase, four-wire
Pendinginan Closed-circuit water cooling
Starting system DC 24 V electric start
Aspiration Turbocharged with an air-to-water charge cooler
Governor Electronic governor
Bahan bakar No. 0 light diesel
Fuel consumption rate 200-210 g/kWh at full load
Insulation class Class H
Ingress protection IP23
Steady-state voltage regulation within +/- 1%

Fuel figures are for 100% load. At 75% load the consumption is about 80% of the full-load figure.

PRP (prime power). Runs continuously under a variable load; a 10% overload is allowed for one hour in every 12 hours of operation.

ESP (standby power). For emergency use; it is not rated for sustained full load and is limited to 200 hours of operation per year.

Configuration

What can be added or changed

Options that change the price and the lead time. Name the ones you need in the quotation request.
Opsi Fungsinya
Saklar pindah otomatis (ATS) Starts the set and transfers the load when the mains fails, and returns it when the mains is stable again.
Base tank or bulk tank Sets the autonomy. A bulk tank with a transfer system is the usual route where a full shift or a whole night has to be covered.
Control panel upgrade An automatic mains failure panel or a remote monitoring panel with alerts, in place of key start/stop.
Voltage and frequency build 380/220 V or a 60 Hz build at 1800 rpm, for sites that are not on the 400 V 50 Hz standard.
Exhaust and silencing Critical or residential grade silencer and exhaust routing, where the site has a noise boundary to respect.
Paralleling module Two or more sets share the load through an equalising control, for sites that grow or need redundancy.
Engine oil heater and coolant pre-heater Keeps the engine warm for a fast, low-wear start in cold weather.

Aplikasi

Where a 1250 kVA set is normally used

  • Site and production power

    Lighting, hoists, tools and workshop loads on one bus, often for the whole working day rather than as standby.

  • Standby for a building

    Hotels, clinics and offices that need the essential bus covered while the mains is down, with the load staged so the set is not asked to take everything at once.

  • Prime power off grid

    Sites with no reliable utility supply, where the set runs as the main source and is serviced on a schedule rather than on failure.

Generators for data centres – all 1250 kVA sets

Pertanyaan

Questions buyers ask about this set

Is this set new or used?

It is a used unit. The condition, the hours and the works we recommend before it goes into service are confirmed in the quotation, and the set can be inspected before it ships.

What is the price of this 1250 kVA set?

There is no price on this page. We quote against the configuration you need – enclosure, tank, control panel, ATS and delivery city – because those change the number more than the base set does. Send the request and you have a written quotation within 24 hours.

What is the fuel consumption of this set?

Consumption follows the load, and the figure we quote is the one on the engine datasheet for this build at 50%, 75% and 100% load. Tell us the load profile you expect and we send those three figures with the quotation.

How long is the delivery time?

The set is available from stock, and the delivery time depends on the options you add and the destination. Give us the delivery city in the request and we confirm the transit time in the quotation.

Can it be supplied for 60 Hz or a different voltage?

Yes. 50 Hz builds run at 1500 rpm and 60 Hz builds at 1800 rpm. Voltage, frequency and phase decide the alternator winding and the control panel, so name them in the request.

Minta penawaran

Quote for model kvg-cummins-1250kva-273

There is no price online for this set. Send the rating you need, the voltage and frequency, the load it has to carry and the delivery city, and we answer with the configuration, the price and the lead time within 24 hours.

Minta Penawaran

Prefer email or WhatsApp? Write to [email protected] atau message us on WhatsApp, quoting model kvg-cummins-1250kva-273. We use the details you send to answer this enquiry and nothing else.

Condition

Used

Daya utama

1250 kVA

Standby power

1400 kVA

Mesin

KTA50-G3

Alternator

LVI634

Reviews

There are no reviews yet.

Be the first to review “Used Cummins 1250 kVA Diesel Generator”

Your email address will not be published. Required fields are marked *